<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-15 07-37-58
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 66 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 3.0 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 63 kHz 19020 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,3 dBr 2,15 dBr 4,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sinfonia nro 45 f-molli (Jaahyvaissinfonia): I. Allegr...(Haydn)"
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2024/10/15 7.36.54 Total samples: 19020 Equivalent time: 0:15:51 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,1 dBr MIN: 0,3 dBr AVE: 2,15 dBr % above 12,2 dBr: 0,0 Last value: 1,3 dBr (2024/10/15 7.36.53) 07.24 07.26 07.28 07.30 07.32 07.34 07.36 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr]